• Availability & Price
  • Search SKU
Filter by attributes
  • Configuration
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Override Functionality
  • Seal Material
More Filters...
Filter by manufacturer

Directional Control Proportional Valves

Picture for category Directional Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMConfigurationOverride FunctionalitySeal MaterialMaximum Inlet Pressure RatingFlow RateMaximum Inlet Pressure RatingMaximum Tank PressureFunctionSeal MaterialMaximum Flow RateLeak RateHysteresisFor Fluid TypeMaximum Operating TemperatureValve MaterialOverride FunctionalityMinimum Operating TemperatureCurrentCavity SizeResponse TimePower ConsumptionFilter Efficiency RatingMaximum Kinematic ViscosityConfigurationMaximum Operating PressureOperating TemperatureCoil Nut Tightening TorqueActuation TypeVariation of Opening PointFlow RateFrequencyCoil TypeFlow Rate AccuracyWeightOperation TypeDivisionBody MaterialInstallation Torque
DSP105C1
Backordered
6 in stock
$198.27/each
EANormally ClosedN/AD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN210 bar3000 psiProportional Directional ControlD-Ring (Standard32 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+93 °CAll parts steel. All operating parts hardened steelN/A-37 °C2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed210 bar-37 to +93 °C3 lb-ftElectrical25% - 30% of Input Signal32 L/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.57 lbSolenoid operatedHydraulic Systems DivisionN/A25 lb-ft
DSP105C1M
Backordered
Backordered
$194.11/each
EANormally ClosedPush and PullD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN210 bar210 barProportional Directional ControlD-Ring (Standard8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+200 °FAll parts steel. All operating parts hardened steelPush and Pull-35 °F2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed210 bar-37 to +93 °C3 lb-ftElectrical, Manual25% - 30% of Input Signal32 L/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.28 kgSolenoid operated, Manually operatedHydraulic Systems DivisionN/A25 lb-ft
DSP105C1V
Backordered
Backordered
$167.79/each
EANormally ClosedN/AFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN210 bar210 barProportional Directional ControlFluorocarbon32 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steelN/A-26 °C2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed3000 psi-15 to +400 °F3 lb-ftElectrical25% - 30% of Input Signal32 L/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.28 kgSolenoid operatedHydraulic Systems DivisionN/A34 Nm
DSP105C4
Backordered
2 Limited Stock
$198.27/each
EAFloating CenterN/AD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN210 bar210 barProportional Directional ControlD-Ring (Standard32 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+200 °FAll parts steel. All operating parts hardened steelN/A-35 °F2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Floating Center210 bar-35 to +200 °F3 lb-ftElectrical25% - 30% of Input Signal32 L/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.57 lbSolenoid operatedHydraulic Systems DivisionN/A25 lb-ft
DSP105C4M
Backordered
Backordered
$194.11/each
EAFloating CenterPush and PullD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN3000 psi210 barProportional Directional ControlD-Ring (Standard8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+200 °FAll parts steel. All operating parts hardened steelPush and Pull-35 °F2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Floating Center210 bar-37 to +93 °C4.1 NmElectrical, Manual25% - 30% of Input Signal8.5 Gal/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.57 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A25 lb-ft
DSP105C4V
Backordered
Backordered
$167.79/each
EAFloating CenterN/AFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN210 bar210 barProportional Directional ControlFluorocarbon8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steelN/A-15 °F2.33 @ 12 VDC, 1.17 @ 24 VDC AC10-450 ms28 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Floating Center3000 psi-15 to +400 °F3 lb-ftElectrical25% - 30% of Input Signal8.5 Gal/min100-400 Hz5/8" Super Coil High Watt (CAP)+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.28 kgSolenoid operatedHydraulic Systems DivisionN/A34 Nm
GP02511N
Backordered
Backordered
$224.19/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN350 bar210 barProportional Directional ControlNitrile15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steelNon-Detented-34 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed5000 psi-30 to +250 °F4.1 NmElectrical, Manual25% - 30% of Input Signal15, 17 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm
GP02512N
Backordered
Backordered
$235.71/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN5000 psi210 barProportional Directional ControlNitrile4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelDetented-30 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed5000 psi-34 to +121 °C4.1 NmElectrical, Manual25% - 30% of Input Signal4, 4.5 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm
GP0251L1N
Backordered
Backordered
$274.48/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN5000 psi3000 psiProportional Directional ControlNitrile3.4, 5.3 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelNon-Detented-30 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-30 to +250 °F3 lb-ftElectrical, Manual25% - 30% of Input Signal0.9, 1.4 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm
GP0251L2N
Backordered
Backordered
$274.48/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN350 bar210 barProportional Directional ControlNitrile3.4, 5.3 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steelDetented-34 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-30 to +250 °F3 lb-ftElectrical, Manual25% - 30% of Input Signal0.9, 1.4 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.15 kgSolenoid operated, Manually operatedHydraulic Systems DivisionN/A22 lb-ft
GP0251LN
Backordered
Backordered
$230.30/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN350 bar3000 psiProportional Directional ControlNitrile0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelN/A-30 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed5000 psi-30 to +250 °F4.1 NmElectrical25% - 30% of Input Signal0.9, 1.4 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operatedHydraulic Systems DivisionN/A22 lb-ft
GP0251LV
Backordered
Backordered
$242.52/each
EANormally ClosedN/AFluorocarbon5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN5000 psi3000 psiProportional Directional ControlFluorocarbon3.4, 5.3 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steelN/A-26 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-15 to +400 °F3 lb-ftElectrical25% - 30% of Input Signal3.4, 5.3 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.15 kgSolenoid operatedHydraulic Systems DivisionN/A22 lb-ft
GP0251N
Backordered
Backordered
$182.36/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN350 bar210 barProportional Directional ControlNitrile4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steelN/A-30 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-30 to +250 °F4.1 NmElectrical25% - 30% of Input Signal15, 17 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operatedHydraulic Systems DivisionN/A22 lb-ft
GP0251V
Backordered
Backordered
$203.51/each
EANormally ClosedN/AFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN350 bar3000 psiProportional Directional ControlFluorocarbon4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steelN/A-26 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-26 to +204 °C3 lb-ftElectrical25% - 30% of Input Signal15, 17 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operatedHydraulic Systems DivisionN/A22 lb-ft
GP02521N
Backordered
Backordered
$224.19/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MIN5000 psi210 barProportional Directional ControlNitrile4.5, 5.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelNon-Detented-34 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed5000 psi-34 to +121 °C3 lb-ftElectrical, Manual25% - 30% of Input Signal4.5, 5.5 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm
GP02522N
Backordered
Backordered
$235.71/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MIN350 bar3000 psiProportional Directional ControlNitrile4.5, 5.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelDetented-34 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-30 to +250 °F3 lb-ftElectrical, Manual25% - 30% of Input Signal17, 21 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm
GP02522V
Backordered
Backordered
$247.22/each
EANormally ClosedDetentedFluorocarbon5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MIN350 bar210 barProportional Directional ControlFluorocarbon17, 21 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steelDetented-15 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-15 to +400 °F3 lb-ftElectrical, Manual25% - 30% of Input Signal17, 21 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A22 lb-ft
GP0252N
Backordered
Backordered
$182.36/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MIN350 bar210 barProportional Directional ControlNitrile4.5, 5.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steelN/A-34 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Normally Closed350 bar-30 to +250 °F3 lb-ftElectrical25% - 30% of Input Signal17, 21 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.15 kgSolenoid operatedHydraulic Systems DivisionN/A22 lb-ft
GP02531N
Backordered
Backordered
$224.19/each
EAFloating CenterNon-DetentedNitrile5000 PSI, 350 BAR2.7, 4 GAL/MIN, 10, 15 L/MIN5000 psi3000 psiProportional Directional ControlNitrile10, 15 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steelNon-Detented-30 °F1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Floating Center350 bar-34 to +121 °C4.1 NmElectrical, Manual25% - 30% of Input Signal10, 15 L/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.34 lbSolenoid operated, Manually operatedHydraulic Systems DivisionN/A22 lb-ft
GP02531V
Backordered
Backordered
$247.22/each
EAFloating CenterNon-DetentedFluorocarbon5000 PSI, 350 BAR2.7, 4 GAL/MIN, 10, 15 L/MIN5000 psi3000 psiProportional Directional ControlFluorocarbon10, 15 L/min10 @ 3000 PSI (210 BAR) cm3/minLess than 6%Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steelNon-Detented-26 °C1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC AC08-450 ms14, 19 WISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)Floating Center350 bar-26 to +204 °C3 lb-ftElectrical, Manual25% - 30% of Input Signal2.7, 4 Gal/min100-400 Hz1/2" Super Coil+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator0.15 kgSolenoid operated, Manually operatedHydraulic Systems DivisionN/A30 Nm