- Availability & Price
- Search SKU
Filter by attributes
- Configuration
- Flow Rate
- Maximum Inlet Pressure Rating
- Override Functionality
- Seal Material
Filter by manufacturer
Directional Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | SKU | Availability | Partner Available | Price | UOM | Configuration | Override Functionality | Seal Material | Maximum Inlet Pressure Rating | Flow Rate | Maximum Inlet Pressure Rating | Maximum Tank Pressure | Function | Seal Material | Maximum Flow Rate | Leak Rate | Hysteresis | For Fluid Type | Maximum Operating Temperature | Valve Material | Override Functionality | Minimum Operating Temperature | Current | Cavity Size | Response Time | Power Consumption | Filter Efficiency Rating | Maximum Kinematic Viscosity | Configuration | Maximum Operating Pressure | Operating Temperature | Coil Nut Tightening Torque | Actuation Type | Variation of Opening Point | Flow Rate | Frequency | Coil Type | Flow Rate Accuracy | Weight | Operation Type | Division | Body Material | Installation Torque |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DSP105C1 | Backordered | 6 in stock | $198.27/each | EA | Normally Closed | N/A | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 210 bar | 3000 psi | Proportional Directional Control | D-Ring (Standard | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +93 °C | All parts steel. All operating parts hardened steel | N/A | -37 °C | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 210 bar | -37 to +93 °C | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 32 L/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.57 lb | Solenoid operated | Hydraulic Systems Division | N/A | 25 lb-ft | |
| DSP105C1M | Backordered | Backordered | $194.11/each | EA | Normally Closed | Push and Pull | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 210 bar | 210 bar | Proportional Directional Control | D-Ring (Standard | 8.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +200 °F | All parts steel. All operating parts hardened steel | Push and Pull | -35 °F | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 210 bar | -37 to +93 °C | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 32 L/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.28 kg | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 25 lb-ft | |
| DSP105C1V | Backordered | Backordered | $167.79/each | EA | Normally Closed | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 210 bar | 210 bar | Proportional Directional Control | Fluorocarbon | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +400 °F | All parts steel. All operating parts hardened steel | N/A | -26 °C | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 3000 psi | -15 to +400 °F | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 32 L/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.28 kg | Solenoid operated | Hydraulic Systems Division | N/A | 34 Nm | |
| DSP105C4 | Backordered | 2 Limited Stock | $198.27/each | EA | Floating Center | N/A | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 210 bar | 210 bar | Proportional Directional Control | D-Ring (Standard | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +200 °F | All parts steel. All operating parts hardened steel | N/A | -35 °F | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Floating Center | 210 bar | -35 to +200 °F | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 32 L/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.57 lb | Solenoid operated | Hydraulic Systems Division | N/A | 25 lb-ft | |
| DSP105C4M | Backordered | Backordered | $194.11/each | EA | Floating Center | Push and Pull | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 3000 psi | 210 bar | Proportional Directional Control | D-Ring (Standard | 8.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +200 °F | All parts steel. All operating parts hardened steel | Push and Pull | -35 °F | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Floating Center | 210 bar | -37 to +93 °C | 4.1 Nm | Electrical, Manual | 25% - 30% of Input Signal | 8.5 Gal/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.57 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 25 lb-ft | |
| DSP105C4V | Backordered | Backordered | $167.79/each | EA | Floating Center | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | 210 bar | 210 bar | Proportional Directional Control | Fluorocarbon | 8.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +204 °C | All parts steel. All operating parts hardened steel | N/A | -15 °F | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | C10-4 | 50 ms | 28 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Floating Center | 3000 psi | -15 to +400 °F | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 8.5 Gal/min | 100-400 Hz | 5/8" Super Coil High Watt (CAP) | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.28 kg | Solenoid operated | Hydraulic Systems Division | N/A | 34 Nm | |
| GP02511N | Backordered | Backordered | $224.19/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | 350 bar | 210 bar | Proportional Directional Control | Nitrile | 15, 17 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +250 °F | All parts steel. All operating parts hardened steel | Non-Detented | -34 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 5000 psi | -30 to +250 °F | 4.1 Nm | Electrical, Manual | 25% - 30% of Input Signal | 15, 17 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm | |
| GP02512N | Backordered | Backordered | $235.71/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | 5000 psi | 210 bar | Proportional Directional Control | Nitrile | 4, 4.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | Detented | -30 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 5000 psi | -34 to +121 °C | 4.1 Nm | Electrical, Manual | 25% - 30% of Input Signal | 4, 4.5 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm | |
| GP0251L1N | Backordered | Backordered | $274.48/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | 5000 psi | 3000 psi | Proportional Directional Control | Nitrile | 3.4, 5.3 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | Non-Detented | -30 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -30 to +250 °F | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 0.9, 1.4 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm | |
| GP0251L2N | Backordered | Backordered | $274.48/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | 350 bar | 210 bar | Proportional Directional Control | Nitrile | 3.4, 5.3 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +250 °F | All parts steel. All operating parts hardened steel | Detented | -34 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -30 to +250 °F | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 0.9, 1.4 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.15 kg | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP0251LN | Backordered | Backordered | $230.30/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | 350 bar | 3000 psi | Proportional Directional Control | Nitrile | 0.9, 1.4 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | N/A | -30 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 5000 psi | -30 to +250 °F | 4.1 Nm | Electrical | 25% - 30% of Input Signal | 0.9, 1.4 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP0251LV | Backordered | Backordered | $242.52/each | EA | Normally Closed | N/A | Fluorocarbon | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | 5000 psi | 3000 psi | Proportional Directional Control | Fluorocarbon | 3.4, 5.3 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +400 °F | All parts steel. All operating parts hardened steel | N/A | -26 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -15 to +400 °F | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 3.4, 5.3 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.15 kg | Solenoid operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP0251N | Backordered | Backordered | $182.36/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | 350 bar | 210 bar | Proportional Directional Control | Nitrile | 4, 4.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +250 °F | All parts steel. All operating parts hardened steel | N/A | -30 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -30 to +250 °F | 4.1 Nm | Electrical | 25% - 30% of Input Signal | 15, 17 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP0251V | Backordered | Backordered | $203.51/each | EA | Normally Closed | N/A | Fluorocarbon | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | 350 bar | 3000 psi | Proportional Directional Control | Fluorocarbon | 4, 4.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +400 °F | All parts steel. All operating parts hardened steel | N/A | -26 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -26 to +204 °C | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 15, 17 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP02521N | Backordered | Backordered | $224.19/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | 5000 psi | 210 bar | Proportional Directional Control | Nitrile | 4.5, 5.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | Non-Detented | -34 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 5000 psi | -34 to +121 °C | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 4.5, 5.5 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm | |
| GP02522N | Backordered | Backordered | $235.71/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | 350 bar | 3000 psi | Proportional Directional Control | Nitrile | 4.5, 5.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | Detented | -34 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -30 to +250 °F | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 17, 21 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm | |
| GP02522V | Backordered | Backordered | $247.22/each | EA | Normally Closed | Detented | Fluorocarbon | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | 350 bar | 210 bar | Proportional Directional Control | Fluorocarbon | 17, 21 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +400 °F | All parts steel. All operating parts hardened steel | Detented | -15 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -15 to +400 °F | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 17, 21 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP0252N | Backordered | Backordered | $182.36/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | 350 bar | 210 bar | Proportional Directional Control | Nitrile | 4.5, 5.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +121 °C | All parts steel. All operating parts hardened steel | N/A | -34 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Normally Closed | 350 bar | -30 to +250 °F | 3 lb-ft | Electrical | 25% - 30% of Input Signal | 17, 21 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.15 kg | Solenoid operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP02531N | Backordered | Backordered | $224.19/each | EA | Floating Center | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | 5000 psi | 3000 psi | Proportional Directional Control | Nitrile | 10, 15 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +250 °F | All parts steel. All operating parts hardened steel | Non-Detented | -30 °F | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Floating Center | 350 bar | -34 to +121 °C | 4.1 Nm | Electrical, Manual | 25% - 30% of Input Signal | 10, 15 L/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.34 lb | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 22 lb-ft | |
| GP02531V | Backordered | Backordered | $247.22/each | EA | Floating Center | Non-Detented | Fluorocarbon | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | 5000 psi | 3000 psi | Proportional Directional Control | Fluorocarbon | 10, 15 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | Mineral-based or synthetic hydraulic fluids | +400 °F | All parts steel. All operating parts hardened steel | Non-Detented | -26 °C | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | C08-4 | 50 ms | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | Floating Center | 350 bar | -26 to +204 °C | 3 lb-ft | Electrical, Manual | 25% - 30% of Input Signal | 2.7, 4 Gal/min | 100-400 Hz | 1/2" Super Coil | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 0.15 kg | Solenoid operated, Manually operated | Hydraulic Systems Division | N/A | 30 Nm |
- 1
- 2