MHC-010-SFSD-00B - Standard Pilot Assisted Load Control Valves

Parker’s piloted load control valves are designed to operate independent of downstream pressure to prevent runaway loads under dynamic conditions using a pilot signal, handling pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm).
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU MHC-010-SFSD-00B
$144.86/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Port Sizen/aMounting TypeThreaded Cartridge Valve
Holding Pressure1000 PSI, 69 BARPilot Pressure Ratio7:1
Maximum Flow Rate10 GAL/MIN, 37.5 L/MINAdjustment MechanismStandard (adjustable)
Pressure Control RangeN/AMaximum Flow Rate10 Gal/min
DivisionHydraulic Cartridge Systems DivisionLeak Rate5 @ 80% of setting drops/min
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Operating Temperature+121 °C
DivisionHydraulic Systems DivisionPilot Pressure Ratio7:1
Flow DirectionCylinder port 2, Valve port 3, Pilot port 1FunctionCounterbalance Valve
Port SizeN/ASeal MaterialNitrile
Maximum Inlet Pressure Rating5000 psiValve MaterialAll parts steel. All operating parts hardened steel
Pressure Control SensitivityN/A psiHolding Pressure69 bar
Mounting TypeThreaded Cartridge ValvePressure Control RangeN/A psi
Flow Rate37.5 L/minMinimum Operating Temperature-30 °F
Adjustment MechanismStandard (adjustable)Cavity SizeCDD-1010
Weight0.88 lbMaximum Operating Pressure350 bar
Pilot LocationExternalBody MaterialN/A
Installation Torque68-75 NmMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Actuation TypePilot Operated
Operating Temperature-34 to +121 °C
Product resources