PRH082K30 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU PRH082K30
$95.70/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAAdjustment MechanismKnob
Flow Rate8 GAL/MIN, 30 L/MINSeal MaterialD-Ring (Standard)
Pressure Control Range200-3000 PSI, 13.8-210 BARAdjustment MechanismKnob
Cavity SizeC08-3Minimum Operating Temperature-37 °C
Mounting TypeScrew in cartridge valvePressure Control Range200-3000 psi
Flow Rate30 L/minPressure Control Sensitivity942 per turn psi
Seal MaterialD-ring (Standard)Maximum Tank Pressure350 bar
Maximum Inlet Pressure Rating380 barFunctionPilot Operated
Maximum Drain Flow Rate0.15 Gal/minStandard Setting Pressure1500 psi
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Operating Temperature+93 °C
Valve MaterialAll parts steel. All operating parts hardened steel.Maximum Pressure Setting210 bar
DivisionHydraulic Cartridge Systems DivisionMaximum Flow Rate30 L/min
Operating Temperature-35 to +200 °FActuation TypePressure Sensing
ConfigurationPressure ReducingMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Maximum Operating Pressure5000 psi
DivisionHydraulic Systems DivisionBody MaterialN/A
Installation Torque43-49 NmWeight0.25 lb
Operation TypeAutomatic
Product resources